{"title":"MCIO (SFF-TA-1016)","description":"\u003cp data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eNEXT-GENERATION HIGH SPEED INTERCONNECT SOLUTION - UP TO 64G PAM4\/PCIe\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eGen 4\/PCIe\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eGen 5\/PCIe\u003csup data-mce-fragment=\"1\"\u003e﻿\u003c\/sup\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eGen 6\u003c\/b\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eAmphenol introduces the next-generation OverPass solution - Mini Cool Edge IO. The 0.60mm pitch connector come with a slim form factor design, capable of transmitting high-speed signal up to 64G PAM4\/PCIe\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eGen 4\/PCIe\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eGen 5\/PCIe\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eGen 6, and allowing much greater signal path lengths while maintaining SI performance when compared to conventional pcb routing methods.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eMini Cool Edge IO not only provides a SI performance ready signal transmission but also a new way of system design that is cost-effective, highly modular, scalable, and extremely easy to repair.\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eHigh speed - 64Gb\/s PAM4 \/PCIe\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eGen 4\/PCIe\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eGen 5\/PCIe\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eGen 6 capability\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eSupports both cable and card edge connection\u003c\/li\u003e\n\u003c\/ul\u003e","products":[{"product_id":"mcio-x8-to-2x-mcio-x4-sff-ta-1016-gen5-70cm","title":"DiLinKer MCIO x8 to 2*MCIO x4, SFF-TA-1016 74Pin to 2*SFF-TA-1016 38Pin, PCIe Gen5 Mini Cooledge IO, Double Straight Cable 70cm(CBL-MCIO-1235M5Y)","description":"\u003cp\u003eSplit one PCIe 5.0 MCIO 8x port into two MCIO 4x ports. The DiLinKer RMC74-6891 (70 cm) takes a single MCIO 8x host connector (SFF-TA-1016, 74-pin) and breaks its eight lanes out to two MCIO 4x connectors (SFF-TA-1016, 38-pin), four lanes each — the cable for feeding 4-lane MCIO devices from a board whose headers are all 8-lane.\u003c\/p\u003e\n\u003ch2\u003eWhy this cable\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePCIe 5.0 rated, 32 GT\/s per lane.\u003c\/strong\u003e Two full x4 links at up to about 15.75 GB\/s each; backward compatible with Gen4\/Gen3.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e8 lanes in, 2 × x4 out.\u003c\/strong\u003e A physical lane split — no switch chip, no retimer, no driver.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKeeps everything on MCIO.\u003c\/strong\u003e For chassis where both the host headers and the device ports are MCIO, no adapter generation-mixing needed.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDouble straight construction.\u003c\/strong\u003e Two separate straight legs for clean routing around risers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePassive assembly.\u003c\/strong\u003e No power draw, nothing to configure.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable style=\"border-collapse:collapse;width:100%;font-size:14px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;background:#fafafa;width:38%;\"\u003e\u003cstrong\u003eHost connector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;\"\u003eMCIO 8x, SFF-TA-1016, 74-pin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;background:#fafafa;width:38%;\"\u003e\u003cstrong\u003eDevice connectors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;\"\u003e2 × MCIO 4x, SFF-TA-1016, 38-pin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;background:#fafafa;width:38%;\"\u003e\u003cstrong\u003eLane configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;\"\u003e8 host lanes → 2 × 4 device lanes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;background:#fafafa;width:38%;\"\u003e\u003cstrong\u003ePCIe generation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;\"\u003ePCIe 5.0 (32 GT\/s per lane); backward compatible with 4.0 \/ 3.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;background:#fafafa;width:38%;\"\u003e\u003cstrong\u003eBandwidth per port\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;\"\u003eUp to 128 GT\/s (about 15.75 GB\/s at Gen5 x4)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;background:#fafafa;width:38%;\"\u003e\u003cstrong\u003eProtocol\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;\"\u003ePCIe only — MCIO carries no SAS or SATA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;background:#fafafa;width:38%;\"\u003e\u003cstrong\u003eLength\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;\"\u003e70 cm \/ 27.6 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;background:#fafafa;width:38%;\"\u003e\u003cstrong\u003ePart number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;\"\u003eRMC74-6891\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;background:#fafafa;width:38%;\"\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;\"\u003e6970958106632\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;background:#fafafa;width:38%;\"\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;\"\u003e24 months\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eCompatibility\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eWorks with\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePCIe 5.0 boards with an MCIO 8x (SFF-TA-1016 74-pin) header.\u003c\/li\u003e\n\u003cli\u003eMCIO 4x (38-pin) inputs on NVMe backplanes, U.2 adapters and drive cages.\u003c\/li\u003e\n\u003cli\u003ePCIe 4.0 and 3.0 equipment — links negotiate down automatically.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDoes not work with\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSAS or SATA devices. MCIO carries PCIe lanes only.\u003c\/li\u003e\n\u003cli\u003eSlimSAS (SFF-8654) device ports — for those use the MCIO to SlimSAS version.\u003c\/li\u003e\n\u003cli\u003eOEM systems that re-map the MCIO pinout (some Dell, HPE and Lenovo chassis) — check with us first.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTypical deployments\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGen5 NVMe tier.\u003c\/strong\u003e Feed two 4-lane MCIO device groups from one host header.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBoard refresh.\u003c\/strong\u003e Keep MCIO 4x backplanes when the new platform standardises on 8x headers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRiser-friendly routing.\u003c\/strong\u003e Two straight legs route around risers better than one wide bundle.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eDo I need to enable PCIe bifurcation?\u003c\/h3\u003e\n\u003cp\u003eIf the board wires the MCIO 8x header as a single x8 root port, enable x4x4 bifurcation in the BIOS. Many boards present the header as 2 × x4 or drive it from a PCIe switch, in which case no change is needed. The board manual will say which.\u003c\/p\u003e\n\u003ch3\u003eMCIO 8x and 4x — what is the difference?\u003c\/h3\u003e\n\u003cp\u003eConnector width and lane count: the 8x is 74-pin carrying eight lanes, the 4x is 38-pin carrying four. They use the same SFF-TA-1016 standard family but will not mate with each other, hence this cable.\u003c\/p\u003e\n\u003ch3\u003eCan I run SAS through it?\u003c\/h3\u003e\n\u003cp\u003eNo. The MCIO host port carries PCIe only, so the device side must be PCIe equipment such as an NVMe backplane.\u003c\/p\u003e\n\u003ch3\u003eIs 70 cm fine at Gen5?\u003c\/h3\u003e\n\u003cp\u003eAt 32 GT\/s every centimetre counts. Keep the run direct, avoid sharp folds, and if a link trains below Gen5 check routing first — the hardware will fall back to Gen4 safely.\u003c\/p\u003e\n\u003ch2\u003eIn the box\u003c\/h2\u003e\n\u003cul\u003e\u003cli\u003e1 × MCIO 8x to 2 × MCIO 4x cable, 70 cm (RMC74-6891)\u003c\/li\u003e\u003c\/ul\u003e\n\u003cp\u003eBacked by a 24-month warranty. If a link trains at reduced width or does not appear, contact us with your controller and device models and we will help you isolate the cause.\u003c\/p\u003e\n\u003ch2\u003eRelated\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/diliving.com\/collections\/mini-cooledge-iomcio\"\u003eAll MCIO \/ Mini Cool Edge IO cables\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/diliving.com\/products\/mcio-x8-to-2x-u-2-nvme-adapter-sff-ta-1016-gen5-80cm\"\u003eMCIO x8 to 2× U.2 NVMe, PCIe Gen5, 80 cm\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/diliving.com\/products\/diliving-mcio-x8-to-2-slimsasx4-sff-ta-1016-74pin-to-2-sff-ta-1016-38pin-pcie-gen5-mini-cooledge-io-double-straight-cable-80cmcbl-mcio-1235m5y\"\u003eMCIO x8 to 2× SlimSAS x4, PCIe Gen5, 80 cm\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DiLinKer","offers":[{"title":"Default Title","offer_id":47981326532904,"sku":"B0CJBG4KQ6","price":43.88,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0866\/1460\/6120\/files\/1-1_e515c29b-188a-4954-bf9c-9843332a1357.jpg?v=1712646473"},{"product_id":"slimsas-x8-to-2x-mcio-x4-sff-8654-sff-ta-1016-gen5-80cm","title":"DiLinKer SlimSAS x8 to 2*MCIO x4, SFF-8654 74Pin to 2*SFF-TA-1016 38Pin, PCIe Gen5 Mini Cooledge IO, Double Straight Cable 80cm","description":"\u003cp\u003eThe bridge in the other direction: a SlimSAS 8x host connector (SFF-8654, 74-pin) splits its eight lanes into two MCIO 4x ports (SFF-TA-1016, 38-pin). Use this assembly to attach Gen5 MCIO devices — NVMe adapter cards, front bays, backplanes — to a controller or switch card that still speaks SlimSAS. It is the mirror image of the MCIO-to-SlimSAS fanout and covers the transition window where both standards live in the same chassis.\u003c\/p\u003e\n\u003ch2\u003eWhy this cable\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePCIe 5.0 rated, 32 GT\/s per lane.\u003c\/strong\u003e Two full x4 links, each up to about 15.75 GB\/s; backward compatible with Gen4 and Gen3.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e8 lanes in, 2 × x4 out.\u003c\/strong\u003e A physical lane split — no switch chip, no retimer, nothing to configure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilt to the SFF pinouts.\u003c\/strong\u003e SFF-8654 74-pin on the host side, SFF-TA-1016 38-pin on the device side.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDouble straight construction.\u003c\/strong\u003e Both legs leave the host connector as separate straight runs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePassive assembly.\u003c\/strong\u003e No power draw, no firmware, no driver.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable style=\"border-collapse:collapse;width:100%;font-size:14px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;background:#fafafa;width:38%;\"\u003e\u003cstrong\u003eHost connector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;\"\u003eSlimSAS 8x, SFF-8654, 74-pin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;background:#fafafa;width:38%;\"\u003e\u003cstrong\u003eDevice connectors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;\"\u003e2 × MCIO 4x, SFF-TA-1016, 38-pin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;background:#fafafa;width:38%;\"\u003e\u003cstrong\u003eLane configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;\"\u003e8 host lanes → 2 × 4 device lanes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;background:#fafafa;width:38%;\"\u003e\u003cstrong\u003eInterface speed\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;\"\u003ePCIe 5.0, up to 32 GT\/s per lane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;background:#fafafa;width:38%;\"\u003e\u003cstrong\u003eProtocol\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;\"\u003ePCIe, as determined by the host port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;background:#fafafa;width:38%;\"\u003e\u003cstrong\u003eLength\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;\"\u003e80 cm \/ 31.5 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;background:#fafafa;width:38%;\"\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;\"\u003eB0CGD5G29N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;background:#fafafa;width:38%;\"\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;\"\u003e24 months\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eCompatibility\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eWorks with\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eControllers, switch cards and boards with SlimSAS 8x (SFF-8654) 74-pin ports.\u003c\/li\u003e\n\u003cli\u003eMCIO 4x devices: U.2\/M.2 adapter cards, Gen5 front bays, MCIO backplanes.\u003c\/li\u003e\n\u003cli\u003ePCIe 4.0 and 3.0 equipment — links negotiate down automatically.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDoes not work with\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMCIO 8x (74-pin) device ports — use an 8x-to-8x cable for those.\u003c\/li\u003e\n\u003cli\u003eSAS-only hosts driving NVMe devices — the protocol follows the host port.\u003c\/li\u003e\n\u003cli\u003eDrives connected directly — each MCIO end must meet a port on a card, cage or backplane.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTypical deployments\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eController to Gen5 bays.\u003c\/strong\u003e A SlimSAS-generation card feeding two MCIO U.2 adapters or front bays.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMixed-generation chassis.\u003c\/strong\u003e Keep existing SlimSAS cabling on the host side while moving devices to MCIO.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBalanced lane use.\u003c\/strong\u003e Split one x8 port into two independent x4 devices instead of adding a switch.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eHow is this different from the MCIO x8 to 2×SlimSAS x4 cable?\u003c\/h3\u003e\n\u003cp\u003eDirection and host standard. That cable starts from an MCIO host; this one starts from a SlimSAS 8x host and ends in two MCIO 4x ports. Pick the one whose host connector matches your board.\u003c\/p\u003e\n\u003ch3\u003eDo both MCIO ports run at Gen5?\u003c\/h3\u003e\n\u003cp\u003eYes. Each leg is a full x4 PCIe 5.0 link, subject to what the host port and the device negotiate.\u003c\/p\u003e\n\u003ch3\u003eCan the two legs go to different devices?\u003c\/h3\u003e\n\u003cp\u003eYes. They are independent x4 links — a U.2 adapter on one and an M.2 card or bay on the other works fine, as long as the host port supports the devices.\u003c\/p\u003e\n\u003ch3\u003eWill it work in a PCIe 4.0 system?\u003c\/h3\u003e\n\u003cp\u003eYes. On a Gen4 host both legs negotiate to 16 GT\/s, and on Gen3 hardware to 8 GT\/s. The cable is passive and passes whatever the host and the devices agree on.\u003c\/p\u003e\n\u003ch2\u003eIn the box\u003c\/h2\u003e\n\u003cul\u003e\u003cli\u003e1 × SlimSAS 8x to 2 × MCIO x4 cable, 80 cm (SKU B0CGD5G29N)\u003c\/li\u003e\u003c\/ul\u003e\n\u003cp\u003eBacked by a 24-month warranty. If a link trains at reduced width or does not appear, contact us with your controller and device models and we will help you isolate the cause.\u003c\/p\u003e\n\u003ch2\u003eRelated\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/diliving.com\/collections\/slimsassff-8654\"\u003eAll SlimSAS (SFF-8654) cables\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/diliving.com\/collections\/mini-cooledge-iomcio\"\u003eAll MCIO (Mini Cooledge IO) cables\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/diliving.com\/products\/diliving-mcio-x8-to-2-slimsasx4-sff-ta-1016-74pin-to-2-sff-ta-1016-38pin-pcie-gen5-mini-cooledge-io-double-straight-cable-80cmcbl-mcio-1235m5y\"\u003eMCIO x8 to 2× SlimSAS x4, PCIe Gen5, 80 cm\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DiLinKer","offers":[{"title":"Default Title","offer_id":47981333348648,"sku":"B0CGD5G29N","price":38.58,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0866\/1460\/6120\/files\/ASFDF.jpg?v=1713328501"},{"product_id":"mcio-x8-to-mcio-x8-sff-ta-1016-pcie-gen5-80cm","title":"DiLinKer MCIO x8 to MCIO x8, SFF-TA-1016 74Pin to SFF-TA-1016 74Pin PCIe Gen5 Mini Cooledge IO Cable, 80cm (CBL-MCIO-1232M5)","description":"\u003cp\u003eA straight PCIe 5.0 internal cable with an MCIO 8x connector (SFF-TA-1016, 74-pin) on both ends. All eight lanes pass through at 32 GT\/s per lane, which makes the CBL-MCIO-1232M5 the default run between a current-generation board and anything that presents MCIO on the device side — Gen5 NVMe backplanes, front-panel adapters and MCIO-based drive enclosures.\u003c\/p\u003e\n\u003ch2\u003eWhy this cable\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePCIe 5.0 rated, 32 GT\/s per lane.\u003c\/strong\u003e A full x8 link with headroom for Gen5 NVMe devices; backward compatible with Gen4 and Gen3.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSame standard on both ends.\u003c\/strong\u003e SFF-TA-1016 74-pin to SFF-TA-1016 74-pin — a direct board-to-device run.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e80 cm internal reach.\u003c\/strong\u003e Long enough for front-header to rear-cage routing in most chassis.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDouble straight assembly.\u003c\/strong\u003e Connectors leave in-line for clean, low-crosstalk routing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePassive and maintenance-free.\u003c\/strong\u003e No power, no firmware, no drivers.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable style=\"border-collapse:collapse;width:100%;font-size:14px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;background:#fafafa;width:38%;\"\u003e\u003cstrong\u003eConnectors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;\"\u003eMCIO 8x, SFF-TA-1016, 74-pin (both ends)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;background:#fafafa;width:38%;\"\u003e\u003cstrong\u003eLane configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;\"\u003e8 lanes, 1:1 pass-through\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;background:#fafafa;width:38%;\"\u003e\u003cstrong\u003eInterface speed\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;\"\u003ePCIe 5.0, up to 32 GT\/s per lane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;background:#fafafa;width:38%;\"\u003e\u003cstrong\u003eProtocol\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;\"\u003ePCIe, as determined by the host port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;background:#fafafa;width:38%;\"\u003e\u003cstrong\u003eLength\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;\"\u003e80 cm \/ 31.5 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;background:#fafafa;width:38%;\"\u003e\u003cstrong\u003ePart number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;\"\u003eCBL-MCIO-1232M5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;background:#fafafa;width:38%;\"\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;\"\u003eB0CBBNR2K8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;background:#fafafa;width:38%;\"\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;\"\u003e24 months\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eCompatibility\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eWorks with\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eBoards and backplanes with MCIO 8x (SFF-TA-1016) 74-pin ports.\u003c\/li\u003e\n\u003cli\u003eGen5 NVMe backplanes and MCIO-based U.2 adapters.\u003c\/li\u003e\n\u003cli\u003ePCIe 4.0 and 3.0 MCIO equipment — links negotiate down automatically.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDoes not work with\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSFF-TA-1016 38-pin (x4) ports — this cable is the 74-pin 8x assembly.\u003c\/li\u003e\n\u003cli\u003eSlimSAS (SFF-8654) ports without a cross-standard cable.\u003c\/li\u003e\n\u003cli\u003eDrives connected directly — the far end must meet a port on a backplane, cage or adapter.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTypical deployments\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBoard to backplane.\u003c\/strong\u003e The standard Gen5 run from MCIO board headers to an NVMe backplane.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFront-panel NVMe bays.\u003c\/strong\u003e MCIO headers feeding front U.2\/MCIO bays over 80 cm.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eJBOF and enclosure links.\u003c\/strong\u003e Internal x8 runs inside MCIO-based enclosures.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eWhat is MCIO?\u003c\/h3\u003e\n\u003cp\u003eMCIO (Mini Cool Edge IO) is SFF-TA-1016, the internal storage connector standard designed around PCIe 5.0. The 74-pin 8x plug carries eight lanes; a 38-pin 4x plug carries four.\u003c\/p\u003e\n\u003ch3\u003eCan I use this to split one x8 port into two x4 devices?\u003c\/h3\u003e\n\u003cp\u003eNo — both ends are a single 8x connector and all eight lanes go straight through. For a lane split, use the MCIO x8 to 2×MCIO x4 or MCIO x8 to 2×SlimSAS x4 cables.\u003c\/p\u003e\n\u003ch3\u003eDoes it matter which end goes to the board?\u003c\/h3\u003e\n\u003cp\u003eElectrically no — the assembly is symmetric. Route whichever end reaches your header more cleanly, and keep the run away from sharp metal edges.\u003c\/p\u003e\n\u003ch3\u003eIs 80 cm safe for PCIe 5.0?\u003c\/h3\u003e\n\u003cp\u003eYes, within typical internal routing. Keep bends gentle, avoid running parallel to power cables, and the link will train at full width and speed.\u003c\/p\u003e\n\u003ch2\u003eIn the box\u003c\/h2\u003e\n\u003cul\u003e\u003cli\u003e1 × MCIO x8 to MCIO x8 cable, 80 cm (CBL-MCIO-1232M5, SKU B0CBBNR2K8)\u003c\/li\u003e\u003c\/ul\u003e\n\u003cp\u003eBacked by a 24-month warranty. If a link trains at reduced width or does not appear, contact us with your controller and device models and we will help you isolate the cause.\u003c\/p\u003e\n\u003ch2\u003eRelated\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/diliving.com\/collections\/mini-cooledge-iomcio\"\u003eAll MCIO (Mini Cooledge IO) cables\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/diliving.com\/products\/mcio-x8-to-slimsas-x8-sff-ta-1016-sff-8654-gen5-100cm\"\u003eMCIO x8 to SlimSAS x8, PCIe Gen5, 100 cm\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/diliving.com\/products\/diliving-mcio-x8-to-2-mcio-x4-sff-ta-1016-74pin-to-2-sff-ta-1016-38pin-pcie-gen5-mini-cooledge-io-double-straight-cable-70cmcbl-mcio-1235m5y\"\u003eMCIO x8 to 2× MCIO x4, PCIe Gen5, 70 cm\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DiLinKer","offers":[{"title":"Default Title","offer_id":47981338984744,"sku":"B0CBBNR2K8","price":43.66,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0866\/1460\/6120\/files\/1-1_70d8b5b3-321f-4fc2-90bd-5c2e69c30e5a.jpg?v=1712716984"},{"product_id":"mcio-x8-to-slimsas-x8-sff-ta-1016-sff-8654-gen5-100cm","title":"DiLinKer MCIO x8 to SlimSAS x8, SFF-TA-1016 74Pin to SFF-8654 74Pin, PCIe Gen5 Mini Cooledge IO, Double Straight Cable 100cm (CBL-MCIO-1270S4T2)","description":"\u003cp\u003eOne MCIO 8x host connector (SFF-TA-1016, 74-pin) on one end, one SlimSAS 8x port (SFF-8654, 74-pin) on the other, all eight lanes passed straight through at PCIe 5.0 speed. This is a one-to-one generation bridge, not a fanout: it connects a modern board that exposes MCIO headers to SlimSAS backplanes, drive cages and adapter cards you already run. The CBL-MCIO-1270S4T2 ships as a double straight assembly, 100 cm long.\u003c\/p\u003e\n\u003ch2\u003eWhy this cable\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePCIe 5.0 rated, 32 GT\/s per lane.\u003c\/strong\u003e Up to roughly 15.75 GB\/s per x4 group; backward compatible with Gen4 and Gen3 equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e8 lanes in, 8 lanes out.\u003c\/strong\u003e A straight 1:1 pass-through — no splitting, no switch chip, no retimer.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilt to the SFF pinouts.\u003c\/strong\u003e SFF-TA-1016 74-pin on the host side, SFF-8654 74-pin on the device side.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDouble straight construction.\u003c\/strong\u003e Two parallel straight runs that route cleanly along chassis walls.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePassive assembly.\u003c\/strong\u003e No power draw, no firmware, nothing to configure in the OS.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable style=\"border-collapse:collapse;width:100%;font-size:14px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;background:#fafafa;width:38%;\"\u003e\u003cstrong\u003eHost connector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;\"\u003eMCIO 8x, SFF-TA-1016, 74-pin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;background:#fafafa;width:38%;\"\u003e\u003cstrong\u003eDevice connector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;\"\u003eSlimSAS 8x, SFF-8654, 74-pin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;background:#fafafa;width:38%;\"\u003e\u003cstrong\u003eLane configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;\"\u003e8 host lanes → 8 device lanes (1:1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;background:#fafafa;width:38%;\"\u003e\u003cstrong\u003eInterface speed\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;\"\u003ePCIe 5.0, up to 32 GT\/s per lane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;background:#fafafa;width:38%;\"\u003e\u003cstrong\u003eProtocol\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;\"\u003ePCIe, as determined by the host port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;background:#fafafa;width:38%;\"\u003e\u003cstrong\u003eLength\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;\"\u003e100 cm \/ 39.4 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;background:#fafafa;width:38%;\"\u003e\u003cstrong\u003ePart number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;\"\u003eCBL-MCIO-1270S4T2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;background:#fafafa;width:38%;\"\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;\"\u003eB0CBBMWWNK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;background:#fafafa;width:38%;\"\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;\"\u003e24 months\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eCompatibility\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eWorks with\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eServer and workstation boards with MCIO 8x (SFF-TA-1016) headers, including PCIe 5.0 platforms.\u003c\/li\u003e\n\u003cli\u003eSlimSAS 8x backplanes, drive cages, U.2 adapters and switch cards.\u003c\/li\u003e\n\u003cli\u003ePCIe 4.0 and 3.0 equipment — links negotiate down automatically.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDoes not work with\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSlimSAS 4x (38-pin) ports — this cable is 8x on both ends. For a 4-lane fanout, see the MCIO x8 to 2×SlimSAS x4 cable.\u003c\/li\u003e\n\u003cli\u003eSFF-TA-1016 38-pin (x4) headers without an adapter.\u003c\/li\u003e\n\u003cli\u003eDrives connected directly — the SlimSAS end must meet a port on a backplane, cage or card.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTypical deployments\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePlatform refresh.\u003c\/strong\u003e A new PCIe 5.0 board with MCIO headers driving an existing SlimSAS 8x backplane.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFront-panel to cage routing.\u003c\/strong\u003e MCIO board headers feeding rear drive cages over a 100 cm run.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLab and test benches.\u003c\/strong\u003e One straight 8-lane run between a test board and a SlimSAS device under test.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eMCIO and SlimSAS are both 74-pin — are they interchangeable?\u003c\/h3\u003e\n\u003cp\u003eNo. SFF-TA-1016 (MCIO) and SFF-8654 (SlimSAS) are different standards with different keying and contact layouts, and a plug will not mate with the wrong receptacle. This cable adapts between them at the electrical level.\u003c\/p\u003e\n\u003ch3\u003eIs this a fanout cable?\u003c\/h3\u003e\n\u003cp\u003eNo. All eight lanes pass from the MCIO end to the SlimSAS end as one x8 link. If you need to split eight lanes into two x4 ports, use the MCIO x8 to 2×SlimSAS x4 cable instead.\u003c\/p\u003e\n\u003ch3\u003eWill it run NVMe?\u003c\/h3\u003e\n\u003cp\u003eYes, if the host port carries PCIe. The cable is protocol-agnostic; NVMe, SAS or SATA traffic follows what the host and device negotiate.\u003c\/p\u003e\n\u003ch3\u003eWhy 100 cm?\u003c\/h3\u003e\n\u003cp\u003eThe long reach suits tower servers and 2U chassis where the board headers and the drive cage sit far apart. Keep the run direct and avoid sharp folds to preserve Gen5 signal integrity.\u003c\/p\u003e\n\u003ch2\u003eIn the box\u003c\/h2\u003e\n\u003cul\u003e\u003cli\u003e1 × MCIO x8 to SlimSAS x8 cable, 100 cm (CBL-MCIO-1270S4T2, SKU B0CBBMWWNK)\u003c\/li\u003e\u003c\/ul\u003e\n\u003cp\u003eBacked by a 24-month warranty. If a link trains at reduced width or does not appear, contact us with your controller and device models and we will help you isolate the cause.\u003c\/p\u003e\n\u003ch2\u003eRelated\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/diliving.com\/collections\/mini-cooledge-iomcio\"\u003eAll MCIO (Mini Cooledge IO) cables\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/diliving.com\/collections\/slimsassff-8654\"\u003eAll SlimSAS (SFF-8654) cables\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/diliving.com\/products\/mcio-x8-to-mcio-x8-sff-ta-1016-pcie-gen5-80cm\"\u003eMCIO x8 to MCIO x8, PCIe Gen5, 80 cm\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DiLinKer","offers":[{"title":"Default Title","offer_id":47981340000552,"sku":"B0CBBMWWNK","price":43.66,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0866\/1460\/6120\/files\/1-1_9027b76a-b764-4e2e-afe4-24a0524ff956.jpg?v=1712718316"},{"product_id":"mcio-x8-to-2x-u-2-nvme-adapter-sff-ta-1016-gen5-80cm","title":"DiLinKer MCIO x8 to 2*U.2 NVMe Adapter, SFF-TA-1016 74Pin to 2*SFF-8639 68Pin, PCIe Gen5 Mini Cooledge IO Cable with Power, 80cm","description":"\u003cp\u003e\u003cstrong\u003eOne MCIO port, two U.2 drives.\u003c\/strong\u003e The DiLinKer RMC74-8986-AX1 is an 80 cm internal PCIe 5.0 cable that splits a single MCIO 8x host connector (SFF-TA-1016, 74-pin) into two independent U.2 NVMe device connectors (SFF-8639, 68-pin). The eight host lanes are broken out as two full x4 links, so each drive trains at its own width and generation — a PCIe 5.0 drive reaches its rated throughput on one port while a PCIe 4.0 drive runs at Gen4 on the other, with no PCIe switch card, no riser and no driver to install.\u003c\/p\u003e\n\n\u003ch2\u003eWhy this adapter cable\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003e8 lanes in, 2 × x4 out.\u003c\/strong\u003e Each U.2 bay gets a dedicated PCIe x4 link instead of sharing bandwidth through a bridge chip.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePCIe 5.0 rated, 32 GT\/s per lane.\u003c\/strong\u003e Up to roughly 15.75 GB\/s per port. Fully backward compatible with PCIe 4.0 and PCIe 3.0 hosts and drives, so it also works on older platforms.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower is carried in the assembly.\u003c\/strong\u003e The U.2 side receives 12 V through the integrated power lead, so drives run without a backplane or a separate SATA power run.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBuilt to the SFF pinouts.\u003c\/strong\u003e Host side SFF-TA-1016 74-pin, device side SFF-8639 68-pin — the two connector standards the drives and boards are actually specified against.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e80 cm of reach.\u003c\/strong\u003e Long enough to route from a mid-board MCIO header to a rear drive cage in 1U and 2U chassis without strain on the connector.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePassive and firmware-free.\u003c\/strong\u003e No retimer, no power-sequencing logic, no BIOS or OS setting specific to the cable itself.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable style=\"border-collapse:collapse;width:100%;font-size:14px;\"\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;background:#fafafa;width:38%;\"\u003e\u003cstrong\u003eHost connector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;\"\u003eMCIO 8x, SFF-TA-1016, 74-pin\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;background:#fafafa;\"\u003e\u003cstrong\u003eDevice connectors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;\"\u003e2 × U.2 (SFF-8639), 68-pin\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;background:#fafafa;\"\u003e\u003cstrong\u003eLane configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;\"\u003e8 host lanes → 2 × 4 device lanes\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;background:#fafafa;\"\u003e\u003cstrong\u003ePCIe generation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;\"\u003ePCIe 5.0 (32 GT\/s per lane); backward compatible with 4.0 \/ 3.0\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;background:#fafafa;\"\u003e\u003cstrong\u003eBandwidth per port\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;\"\u003eUp to 128 GT\/s (about 15.75 GB\/s at Gen5 x4)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;background:#fafafa;\"\u003e\u003cstrong\u003eLength\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;\"\u003e80 cm \/ 31.5 in\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;background:#fafafa;\"\u003e\u003cstrong\u003ePower\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;\"\u003eIntegrated power lead from the system PSU\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;background:#fafafa;\"\u003e\u003cstrong\u003eProtocol\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;\"\u003eNVMe over PCIe only — does not carry SAS or SATA\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;background:#fafafa;\"\u003e\u003cstrong\u003ePart number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;\"\u003eRMC74-8986-AX1\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;background:#fafafa;\"\u003e\u003cstrong\u003eSKU \/ EAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;\"\u003eB0CCV4PXV8 \/ 6970958109732\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;background:#fafafa;\"\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;\"\u003e104 g\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;background:#fafafa;\"\u003e\u003cstrong\u003eOperating temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;\"\u003e0 – 70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;background:#fafafa;\"\u003e\u003cstrong\u003eCompliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;\"\u003eSFF-TA-1016, SFF-8639, RoHS\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;background:#fafafa;\"\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;\"\u003e24 months\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCompatibility\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eWorks with\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eServer and workstation boards that expose an MCIO 8x (SFF-TA-1016 74-pin) port — common on PCIe 5.0 platforms from Supermicro, ASUS, ASRock Rack, Gigabyte, Tyan, and on AMD EPYC and Intel Xeon Scalable reference designs.\u003c\/li\u003e\n  \u003cli\u003eU.2 NVMe SSDs such as Samsung PM9A3 \/ PM1733 \/ PM1743, Micron 7450 \/ 9300, Kioxia CM6 \/ CD6, Solidigm D7-P5510 \/ D5-P5316 and Intel P4510 \/ P5520 series.\u003c\/li\u003e\n  \u003cli\u003eU.2 drive cages and hot-swap bays that terminate in SFF-8639.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDoes not work with\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eSlimSAS (SFF-8654) or MiniSAS HD (SFF-8643) hosts — those need a different cable in this range, not an adapter on this one.\u003c\/li\u003e\n  \u003cli\u003eSAS or SATA drives. The MCIO host port carries PCIe lanes only.\u003c\/li\u003e\n  \u003cli\u003eOEM systems that re-purpose the MCIO connector with a proprietary pinout (some Dell, HPE and Lenovo chassis). Check the board manual, or message us with your model before ordering.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eTypical deployments\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBoot and log tier.\u003c\/strong\u003e Two U.2 drives in mirror from a single MCIO port, leaving the other ports free for data drives.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAI and HPC nodes.\u003c\/strong\u003e Gen5 U.2 for dataset staging where the drive, not the cable, is the bottleneck.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e1U \/ 2U chassis with rear cages.\u003c\/strong\u003e The 80 cm run reaches the back of the case without a mid-board backplane.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWorkstations building a ZFS or Storage Spaces pool.\u003c\/strong\u003e Two NVMe devices without spending a PCIe slot on a quad M.2 or U.2 card.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eWhich MCIO breakout cable do you need?\u003c\/h2\u003e\n\u003ctable style=\"border-collapse:collapse;width:100%;font-size:14px;\"\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px 10px;background:#f2f2ef;text-align:left;\"\u003eHost port\u003c\/th\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px 10px;background:#f2f2ef;text-align:left;\"\u003eDevice side\u003c\/th\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px 10px;background:#f2f2ef;text-align:left;\"\u003eUse when\u003c\/th\u003e\n\u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;\"\u003eMCIO 8x\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;\"\u003e2 × U.2 (SFF-8639)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;\"\u003e\n\u003cstrong\u003eThis product\u003c\/strong\u003e — direct-attach NVMe drives or a U.2 cage\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;\"\u003eMCIO 8x\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;\"\u003e2 × MiniSAS HD (SFF-8643)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;\"\u003eYou already own an SFF-8643 backplane or U.2 adapter (\u003ca href=\"https:\/\/diliving.com\/products\/mcio-x8-to-2x-minisas-hd-sff-ta-1016-sff-8643-gen4-80cm\"\u003eGen4 version\u003c\/a\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;\"\u003eMCIO 8x\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;\"\u003e1 × SlimSAS 8x (SFF-8654)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;\"\u003eBoard-to-board link to a SlimSAS backplane (\u003ca href=\"https:\/\/diliving.com\/collections\/slimsassff-8654\"\u003eSlimSAS cables\u003c\/a\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;\"\u003eSlimSAS 8x\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;\"\u003e2 × U.2 (SFF-8639)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;\"\u003eYour board has SlimSAS headers rather than MCIO (\u003ca href=\"https:\/\/diliving.com\/collections\/u-2-nvmesff-8639\"\u003eU.2 cables\u003c\/a\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\n\u003ch3\u003eDoes this cable work on a PCIe 4.0 motherboard?\u003c\/h3\u003e\n\u003cp\u003eYes. The cable is passive, so the link speed is negotiated between the host and the drive. A Gen4 board with Gen4 drives trains at 16 GT\/s; a Gen5 drive on a Gen4 board simply runs at Gen4. Nothing needs to be configured.\u003c\/p\u003e\n\n\u003ch3\u003eDo I have to enable PCIe bifurcation?\u003c\/h3\u003e\n\u003cp\u003eIt depends on how your board wires the MCIO port. Many server boards ship the MCIO 8x header already configured as 2 × x4, or drive it from a PCIe switch, in which case there is nothing to change. If your board exposes that header as a single x8 root port, enable x4x4 bifurcation for that port in the BIOS. The board manual will state which case applies.\u003c\/p\u003e\n\n\u003ch3\u003eDo the U.2 drives need their own power cable?\u003c\/h3\u003e\n\u003cp\u003eNo separate SATA or Molex run to each drive — power is delivered through the integrated lead in this assembly. You connect that lead to the system PSU once, and both U.2 connectors are powered from it.\u003c\/p\u003e\n\n\u003ch3\u003eWhat is the difference between MCIO and SlimSAS?\u003c\/h3\u003e\n\u003cp\u003eBoth are compact internal PCIe connectors with 8-lane (74-pin) variants, but they are different standards with different housings and latches, and they are not interchangeable. MCIO is SFF-TA-1016 and is the connector most PCIe 5.0 server boards use for NVMe breakout. SlimSAS is SFF-8654 and is also used for SAS 4.0. If you are unsure which one is on your board, send us a photo of the header and we will confirm.\u003c\/p\u003e\n\n\u003ch3\u003eCan I connect SAS or SATA drives to this cable?\u003c\/h3\u003e\n\u003cp\u003eNo. The MCIO 8x port carries PCIe lanes only, so the device side must be a U.2 NVMe drive or a U.2 NVMe backplane. For SAS drives, use a SlimSAS to SAS fan-out cable instead.\u003c\/p\u003e\n\n\u003ch3\u003eWill it work in a Dell, HPE or Lenovo server?\u003c\/h3\u003e\n\u003cp\u003eOften not, unless the system uses the standard SFF-TA-1016 pinout. Several OEMs re-purpose the same physical connector with a proprietary lane order, and a standard cable will either not link or will link at reduced width. Tell us the exact model before ordering and we will check it against our pinout notes.\u003c\/p\u003e\n\n\u003ch3\u003eIs 80 cm too long for PCIe 5.0?\u003c\/h3\u003e\n\u003cp\u003eAt 32 GT\/s every centimetre adds insertion loss, so keep the run as short as your chassis allows and avoid tight bends or sharp folds. 80 cm is intended for in-chassis routing to a rear cage. If a link trains below Gen5, cable length and routing are the first things to check.\u003c\/p\u003e\n\n\u003ch2\u003eIn the box\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e1 × MCIO 8x to 2 × U.2 NVMe adapter cable, 80 cm (RMC74-8986-AX1)\u003c\/li\u003e\n  \u003cli\u003eIntegrated power lead\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eBacked by a 24-month warranty. If a cable arrives damaged or fails to link, contact us with your board model and we will replace it or help you trace the fault.\u003c\/p\u003e\n\n\u003ch2\u003eRelated\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/diliving.com\/collections\/mini-cooledge-iomcio\"\u003eAll MCIO \/ Mini Cool Edge IO cables\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/diliving.com\/collections\/u-2-nvmesff-8639\"\u003eU.2 NVMe (SFF-8639) cables and adapters\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/diliving.com\/products\/mcio-x8-to-2x-minisas-hd-sff-ta-1016-sff-8643-gen4-80cm\"\u003eMCIO x8 to 2× MiniSAS HD, PCIe Gen4, 80 cm\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"DiLinKer","offers":[{"title":"Default Title","offer_id":48720580313384,"sku":"B0CCV4PXV8","price":38.98,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0866\/1460\/6120\/files\/1-1.jpg?v=1712645847"},{"product_id":"mcio-x8-to-2x-slimsas-x4-sff-ta-1016-sff-8654-gen5-80cm","title":"DiLinKer MCIO x8 to 2*SlimSAS x4, SFF-TA-1016 74Pin to 2*SFF-8654 38Pin, PCIe Gen5 Mini Cooledge IO, Double Straight Cable 80cm","description":"\u003cp\u003eA PCIe 5.0 bridge between the two newest internal storage connectors. The DiLinKer DLMC74-8871 takes one MCIO 8x host connector (SFF-TA-1016, 74-pin) and splits its eight lanes into two SlimSAS 4x ports (SFF-8654, 38-pin), four lanes each. Use it to feed SlimSAS-generation backplanes and devices from a board that only exposes MCIO headers — increasingly the case on current PCIe 5.0 platforms.\u003c\/p\u003e\n\u003ch2\u003eWhy this cable\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePCIe 5.0 rated, 32 GT\/s per lane.\u003c\/strong\u003e Two full x4 links, each up to about 15.75 GB\/s, with backward compatibility to Gen4 and Gen3.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e8 lanes in, 2 × x4 out.\u003c\/strong\u003e A physical lane split — no switch chip, no retimer, nothing to configure in the OS.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilt to the SFF pinouts.\u003c\/strong\u003e SFF-TA-1016 on the host side, SFF-8654 38-pin on the device side.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDouble straight construction.\u003c\/strong\u003e Both legs leave the host connector as separate straight runs for clean routing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePassive assembly.\u003c\/strong\u003e No power draw, no firmware, no driver.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable style=\"border-collapse:collapse;width:100%;font-size:14px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;background:#fafafa;width:38%;\"\u003e\u003cstrong\u003eHost connector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;\"\u003eMCIO 8x, SFF-TA-1016, 74-pin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;background:#fafafa;width:38%;\"\u003e\u003cstrong\u003eDevice connectors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;\"\u003e2 × SlimSAS 4x, SFF-8654, 38-pin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;background:#fafafa;width:38%;\"\u003e\u003cstrong\u003eLane configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;\"\u003e8 host lanes → 2 × 4 device lanes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;background:#fafafa;width:38%;\"\u003e\u003cstrong\u003ePCIe generation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;\"\u003ePCIe 5.0 (32 GT\/s per lane); backward compatible with 4.0 \/ 3.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;background:#fafafa;width:38%;\"\u003e\u003cstrong\u003eBandwidth per port\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;\"\u003eUp to 128 GT\/s (about 15.75 GB\/s at Gen5 x4)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;background:#fafafa;width:38%;\"\u003e\u003cstrong\u003eProtocol\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;\"\u003ePCIe only — the MCIO host port carries no SAS or SATA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;background:#fafafa;width:38%;\"\u003e\u003cstrong\u003eLength\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;\"\u003e80 cm \/ 31.5 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;background:#fafafa;width:38%;\"\u003e\u003cstrong\u003ePart number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;\"\u003eDLMC74-8871\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;background:#fafafa;width:38%;\"\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;\"\u003eB0DPMCPHPD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;background:#fafafa;width:38%;\"\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;\"\u003e24 months\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eCompatibility\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eWorks with\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePCIe 5.0 server and workstation boards with an MCIO 8x (SFF-TA-1016 74-pin) header.\u003c\/li\u003e\n\u003cli\u003eSlimSAS 4x (38-pin) inputs on NVMe backplanes, U.2 adapters and drive cages.\u003c\/li\u003e\n\u003cli\u003ePCIe 4.0 and 3.0 equipment — links negotiate down automatically.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDoes not work with\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSlimSAS hosts. This cable is driven from the MCIO side only.\u003c\/li\u003e\n\u003cli\u003eSAS-only controllers. The MCIO port carries PCIe lanes, so SAS backplanes fed from an SAS controller need a SAS cable.\u003c\/li\u003e\n\u003cli\u003eOEM systems that re-map the MCIO pinout (some Dell, HPE and Lenovo chassis) — check with us first.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTypical deployments\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGen5 NVMe tier.\u003c\/strong\u003e Feed a SlimSAS-input NVMe backplane from a Gen5 board without a switch card.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBoard refresh.\u003c\/strong\u003e Keep SlimSAS-generation storage hardware when the new platform only has MCIO headers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDense chassis routing.\u003c\/strong\u003e Two straight 4x legs are easier to dress than one 8x bundle.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eDo I need to enable PCIe bifurcation?\u003c\/h3\u003e\n\u003cp\u003eIf the board wires the MCIO 8x header as a single x8 root port, yes — enable x4x4 bifurcation for that header in the BIOS. Many server boards already present the header as 2 × x4 or drive it from a PCIe switch, in which case no setting is needed. The board manual will say which.\u003c\/p\u003e\n\u003ch3\u003eIs 80 cm too long for PCIe 5.0?\u003c\/h3\u003e\n\u003cp\u003eAt 32 GT\/s, long passive runs leave little signal margin. If a link trains below Gen5, shorten the run, improve routing, or accept Gen4 operation — the hardware negotiates automatically and nothing is damaged.\u003c\/p\u003e\n\u003ch3\u003eCan this cable carry SAS?\u003c\/h3\u003e\n\u003cp\u003eNo. SlimSAS the connector can carry SAS, but your MCIO host port only carries PCIe lanes, so the device side must be PCIe equipment such as an NVMe backplane.\u003c\/p\u003e\n\u003ch3\u003eMCIO or SlimSAS — which one is on my board?\u003c\/h3\u003e\n\u003cp\u003eCheck the header: MCIO (SFF-TA-1016) has a distinct housing and latch from SlimSAS (SFF-8654). Send us a photo of the header if you are unsure and we will identify it.\u003c\/p\u003e\n\u003ch2\u003eIn the box\u003c\/h2\u003e\n\u003cul\u003e\u003cli\u003e1 × MCIO 8x to 2 × SlimSAS 4x cable, 80 cm (SKU B0DPMCPHPD)\u003c\/li\u003e\u003c\/ul\u003e\n\u003cp\u003eBacked by a 24-month warranty. If a link trains at reduced width or does not appear, contact us with your controller and device models and we will help you isolate the cause.\u003c\/p\u003e\n\u003ch2\u003eRelated\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/diliving.com\/collections\/mini-cooledge-iomcio\"\u003eAll MCIO \/ Mini Cool Edge IO cables\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/diliving.com\/collections\/slimsassff-8654\"\u003eAll SlimSAS (SFF-8654) cables\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/diliving.com\/products\/mcio-x8-to-2x-u-2-nvme-adapter-sff-ta-1016-gen5-80cm\"\u003eMCIO x8 to 2× U.2 NVMe, PCIe Gen5, 80 cm\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DiLinKer","offers":[{"title":"Default Title","offer_id":49676532613416,"sku":"B0DPMCPHPD","price":48.88,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0866\/1460\/6120\/files\/FullSizeRender.jpg?v=1735699383"},{"product_id":"mcio-x4-to-u-2-nvme-adapter-sff-ta-1016-sff-8639-70cm","title":"DiLinKer PCIe 5.0 MCIO x4 to U.2 NVMe Adapter, SFF-TA-1016 to SFF-8639 Cable with Power, Cable 70cm","description":"\u003cp\u003eAttach a U.2 (SFF-8639) NVMe drive directly to an MCIO header. This PCIe 5.0 assembly starts with an MCIO 4x connector (SFF-TA-1016, 38-pin) and ends in a U.2 drive interface, with a power branch built into the cable so one part does the whole job. It is the shortest path from a Gen5 board’s MCIO x4 headers to 2.5-inch U.2 NVMe SSDs — no adapter card, no backplane.\u003c\/p\u003e\n\u003ch2\u003eWhy this cable\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePCIe 5.0 rated.\u003c\/strong\u003e A full x4 link at 32 GT\/s per lane — about 15.75 GB\/s to a Gen5 U.2 SSD.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDirect drive attach.\u003c\/strong\u003e Reaches the U.2 drive itself; no backplane or adapter card in between.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower built into the assembly.\u003c\/strong\u003e The cable carries the drive power branch, so you do not need a separate U.2 power adapter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e70 cm of reach.\u003c\/strong\u003e Comfortable routing from board headers to a 2.5-inch drive bay.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePassive assembly.\u003c\/strong\u003e No firmware, no driver, nothing to configure.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable style=\"border-collapse:collapse;width:100%;font-size:14px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;background:#fafafa;width:38%;\"\u003e\u003cstrong\u003eHost connector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;\"\u003eMCIO 4x, SFF-TA-1016, 38-pin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;background:#fafafa;width:38%;\"\u003e\u003cstrong\u003eDevice interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;\"\u003eU.2 NVMe, SFF-8639\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;background:#fafafa;width:38%;\"\u003e\u003cstrong\u003ePower\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;\"\u003eIntegrated power branch for the drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;background:#fafafa;width:38%;\"\u003e\u003cstrong\u003eLane configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;\"\u003e4 lanes, 1:1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;background:#fafafa;width:38%;\"\u003e\u003cstrong\u003eInterface speed\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;\"\u003ePCIe 5.0, up to 32 GT\/s per lane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;background:#fafafa;width:38%;\"\u003e\u003cstrong\u003eLength\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;\"\u003e70 cm \/ 27.6 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;background:#fafafa;width:38%;\"\u003e\u003cstrong\u003eSKU \/ identifier\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;\"\u003eSR-0549-AX1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;background:#fafafa;width:38%;\"\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;\"\u003e24 months\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eCompatibility\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eWorks with\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eBoards with MCIO 4x (SFF-TA-1016) 38-pin headers carrying PCIe.\u003c\/li\u003e\n\u003cli\u003e2.5-inch U.2 (SFF-8639) NVMe SSDs, Gen4 and Gen5.\u003c\/li\u003e\n\u003cli\u003eServer and workstation chassis with standard drive power (SATA-style or MOLEX via the branch).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDoes not work with\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eU.2 drives behind a backplane — for that, run an MCIO cable to the backplane port instead.\u003c\/li\u003e\n\u003cli\u003eM.2 slots — this is a U.2 (2.5-inch) assembly.\u003c\/li\u003e\n\u003cli\u003eSAS\/SATA U.2 drives behind SAS hosts — NVMe requires a PCIe-capable host port.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTypical deployments\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGen5 board to U.2 SSD.\u003c\/strong\u003e The direct MCIO-to-drive run on current platforms.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFront bay NVMe.\u003c\/strong\u003e Feed a 2.5-inch bay from an MCIO header without a backplane.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLab benches.\u003c\/strong\u003e Quick U.2 device attach for testing Gen5 SSDs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eDo I still need a separate power cable for the drive?\u003c\/h3\u003e\n\u003cp\u003eNo. The assembly includes the power branch, so the drive’s power comes along with the data cable from a standard internal power source.\u003c\/p\u003e\n\u003ch3\u003eWill it run a Gen4 U.2 SSD?\u003c\/h3\u003e\n\u003cp\u003eYes. The link negotiates to the device speed, so Gen4 and Gen3 drives run at their rated rates.\u003c\/p\u003e\n\u003ch3\u003eMCIO x4 or x8 — which do I have?\u003c\/h3\u003e\n\u003cp\u003eThe 38-pin plug is x4, the 74-pin plug is x8. This cable is x4; if your header is the 74-pin type, use the MCIO x8 to 2×U.2 NVMe cable instead.\u003c\/p\u003e\n\u003ch3\u003eDoes the drive need to be NVMe?\u003c\/h3\u003e\n\u003cp\u003eFor PCIe hosts, yes — U.2 SAS drives will not enumerate on a PCIe port. The cable itself is passive and carries whatever the host and drive agree on.\u003c\/p\u003e\n\u003ch2\u003eIn the box\u003c\/h2\u003e\n\u003cul\u003e\u003cli\u003e1 × MCIO x4 to U.2 NVMe adapter cable with power, 70 cm (SKU SR-0549-AX1)\u003c\/li\u003e\u003c\/ul\u003e\n\u003cp\u003eBacked by a 24-month warranty. If a link trains at reduced width or does not appear, contact us with your controller and device models and we will help you isolate the cause.\u003c\/p\u003e\n\u003ch2\u003eRelated\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/diliving.com\/collections\/mini-cooledge-iomcio\"\u003eAll MCIO (Mini Cooledge IO) cables\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/diliving.com\/collections\/u-2-nvmesff-8639\"\u003eAll U.2 NVMe (SFF-8639) cables\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/diliving.com\/products\/mcio-x8-to-2x-u-2-nvme-adapter-sff-ta-1016-gen5-80cm\"\u003eMCIO x8 to 2× U.2 NVMe Adapter, PCIe Gen5, 80 cm\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DiLinKer","offers":[{"title":"Default Title","offer_id":50853338415400,"sku":"SR-0549-AX1","price":36.88,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0866\/1460\/6120\/files\/4.jpg?v=1761114105"},{"product_id":"mcio-x8-to-2x-minisas-hd-sff-ta-1016-sff-8643-gen4-80cm","title":"DiLinKer MCIO x8 to 2*MiniSAS-HD x4, SFF-TA-1016 74Pin to 2*SFF-8643 36Pin, PCIe Gen4 Mini Cooledge IO Cable, 80cm","description":"\u003cp\u003e\u003cstrong\u003eKeep your MiniSAS HD backplane, move to a Gen4 MCIO board.\u003c\/strong\u003e The DiLinKer RMC74-8690-AX1 converts one MCIO 8x host connector (SFF-TA-1016, 74-pin) into two MiniSAS HD x4 ports (SFF-8643, 36-pin), 80 cm long. It is the cable you need when the motherboard is new — a PCIe 4.0 server or workstation platform with MCIO headers — but the chassis, drive cage or U.2 adapter you already own terminates in SFF-8643. Instead of replacing the backplane, you change one cable.\u003c\/p\u003e\n\n\u003ch2\u003eWhy this cable\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMCIO host, SFF-8643 device.\u003c\/strong\u003e Splits 8 host lanes into two independent x4 links, each on a standard 36-pin MiniSAS HD plug.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePCIe 4.0, 16 GT\/s per lane.\u003c\/strong\u003e Around 7.88 GB\/s per port — the full bandwidth of a Gen4 x4 NVMe drive, with no switch chip in the path.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProtects existing hardware.\u003c\/strong\u003e Reuse SFF-8643 backplanes, drive cages and U.2 adapters you have already bought and qualified.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTwo links, not one.\u003c\/strong\u003e Both SFF-8643 outputs carry four lanes each, so two devices run at full x4 width simultaneously.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e80 cm for cable management.\u003c\/strong\u003e Enough length to route behind the riser and reach a rear cage without pulling the connector sideways.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePassive assembly.\u003c\/strong\u003e No retimer, no power, no configuration in BIOS or the OS.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable style=\"border-collapse:collapse;width:100%;font-size:14px;\"\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;background:#fafafa;width:38%;\"\u003e\u003cstrong\u003eHost connector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;\"\u003eMCIO 8x, SFF-TA-1016, 74-pin\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;background:#fafafa;\"\u003e\u003cstrong\u003eDevice connectors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;\"\u003e2 × MiniSAS HD, SFF-8643, 36-pin\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;background:#fafafa;\"\u003e\u003cstrong\u003eLane configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;\"\u003e8 host lanes → 2 × 4 device lanes\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;background:#fafafa;\"\u003e\u003cstrong\u003ePCIe generation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;\"\u003ePCIe 4.0 (16 GT\/s per lane); backward compatible with 3.0\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;background:#fafafa;\"\u003e\u003cstrong\u003eBandwidth per port\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;\"\u003e64 GT\/s (about 7.88 GB\/s at Gen4 x4)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;background:#fafafa;\"\u003e\u003cstrong\u003eLength\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;\"\u003e80 cm \/ 31.5 in\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;background:#fafafa;\"\u003e\u003cstrong\u003eProtocol\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;\"\u003eNVMe over PCIe only — the MCIO host port carries no SAS or SATA\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;background:#fafafa;\"\u003e\u003cstrong\u003ePart number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;\"\u003eRMC74-8690-AX1\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;background:#fafafa;\"\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;\"\u003e60 g\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;background:#fafafa;\"\u003e\u003cstrong\u003eCompliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;\"\u003eSFF-TA-1016, SFF-8643, RoHS\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;background:#fafafa;\"\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;\"\u003e24 months\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCompatibility\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eWorks with\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eBoards with an MCIO 8x (SFF-TA-1016 74-pin) header — standard on most PCIe 4.0 server and workstation platforms from Supermicro, ASUS, ASRock Rack, Gigabyte and Tyan.\u003c\/li\u003e\n  \u003cli\u003eMiniSAS HD x4 NVMe backplanes and drive cages with SFF-8643 inputs.\u003c\/li\u003e\n  \u003cli\u003eU.2 adapters and converters that take an SFF-8643 input and present an SFF-8639 drive connector.\u003c\/li\u003e\n  \u003cli\u003ePCIe 3.0 equipment — the link negotiates down to 8 GT\/s automatically.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDoes not work with\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003ePCIe 5.0 links. SFF-8643 is a Gen4-generation interface; use the MCIO to U.2 or MCIO to SlimSAS version if you need 32 GT\/s.\u003c\/li\u003e\n  \u003cli\u003eSAS or SATA drives. The SFF-8643 connector can carry SAS in other designs, but your MCIO host port carries PCIe lanes only, so the device must be NVMe.\u003c\/li\u003e\n  \u003cli\u003eSlimSAS (SFF-8654) or U.2 (SFF-8639) device connectors — this cable does not adapt to those directly.\u003c\/li\u003e\n  \u003cli\u003eOEM systems that re-map the MCIO pinout (some Dell, HPE and Lenovo chassis). Ask us with your model number first.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eTypical deployments\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBoard refresh in an existing 2U chassis.\u003c\/strong\u003e New Gen4 platform, existing SFF-8643 NVMe backplane, no chassis replacement.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNVMe tier next to SAS storage.\u003c\/strong\u003e Add two NVMe devices to a server that already has a MiniSAS HD cage.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWorkstation scratch volume.\u003c\/strong\u003e Two Gen4 U.2 drives through SFF-8643 adapters, without using a PCIe slot.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLab and validation rigs.\u003c\/strong\u003e Swap drives and backplanes between MCIO and SFF-8643 hardware with one cable.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eWhich MCIO breakout cable do you need?\u003c\/h2\u003e\n\u003ctable style=\"border-collapse:collapse;width:100%;font-size:14px;\"\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px 10px;background:#f2f2ef;text-align:left;\"\u003eDevice side\u003c\/th\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px 10px;background:#f2f2ef;text-align:left;\"\u003eBest for\u003c\/th\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px 10px;background:#f2f2ef;text-align:left;\"\u003eGeneration\u003c\/th\u003e\n\u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;\"\u003e2 × MiniSAS HD (SFF-8643)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;\"\u003e\n\u003cstrong\u003eThis product\u003c\/strong\u003e — reuse an existing SFF-8643 backplane or U.2 adapter\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;\"\u003ePCIe 4.0\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;\"\u003e2 × U.2 (SFF-8639)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;\"\u003eDirect-attach U.2 drives, highest bandwidth (\u003ca href=\"https:\/\/diliving.com\/products\/mcio-x8-to-2x-u-2-nvme-adapter-sff-ta-1016-gen5-80cm\"\u003eMCIO to 2× U.2\u003c\/a\u003e)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;\"\u003ePCIe 5.0\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;\"\u003e1 × SlimSAS 8x (SFF-8654)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;\"\u003eSlimSAS backplane, 8 lanes in one connector (\u003ca href=\"https:\/\/diliving.com\/collections\/slimsassff-8654\"\u003eSlimSAS cables\u003c\/a\u003e)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 10px;\"\u003ePCIe 5.0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\n\u003ch3\u003eDoes this cable support PCIe 5.0?\u003c\/h3\u003e\n\u003cp\u003eNo. SFF-8643 is a 4-lane interface defined around the Gen4 generation, and this assembly is specified to 16 GT\/s per lane. If your drives and board are Gen5, use the \u003ca href=\"https:\/\/diliving.com\/products\/mcio-x8-to-2x-u-2-nvme-adapter-sff-ta-1016-gen5-80cm\"\u003eMCIO to 2× U.2 version\u003c\/a\u003e, which is rated for 32 GT\/s.\u003c\/p\u003e\n\n\u003ch3\u003eWhy use SFF-8643 at all instead of going straight to U.2?\u003c\/h3\u003e\n\u003cp\u003eBecause the hardware you already own decides it. A Gen4 x4 NVMe link delivers the same 7.88 GB\/s whether it passes through a U.2 connector or an SFF-8643 connector — the connector is not the bottleneck. If your backplane or drive cage is SFF-8643, this cable is the cheaper answer than replacing the cage.\u003c\/p\u003e\n\n\u003ch3\u003eDo I need to enable PCIe bifurcation?\u003c\/h3\u003e\n\u003cp\u003eOnly if your board wires the MCIO 8x header as a single x8 root port. Many server boards ship that header already split as 2 × x4, or drive it from a PCIe switch, in which case no setting is needed. Check the board manual for that specific header.\u003c\/p\u003e\n\n\u003ch3\u003eCan I connect SAS drives to the SFF-8643 ends?\u003c\/h3\u003e\n\u003cp\u003eNo. The connector type alone does not decide the protocol — the host port does, and MCIO carries PCIe lanes only. Put a SAS drive behind this cable and it will not be detected. For SAS, use a SlimSAS to SAS cable with an HBA that speaks SAS.\u003c\/p\u003e\n\n\u003ch3\u003eBoth ports at full speed, or do they share bandwidth?\u003c\/h3\u003e\n\u003cp\u003eBoth are full x4 links. The eight host lanes are physically split 4 + 4, so each port has its own four lanes. There is no bridge chip and no shared uplink.\u003c\/p\u003e\n\n\u003ch3\u003eWill it work with a U.2 adapter that has an SFF-8643 input?\u003c\/h3\u003e\n\u003cp\u003eYes — that is one of the main uses. The adapter converts the 4-lane link to an SFF-8639 drive connector; the cable only has to deliver four clean PCIe lanes to it, which it does at Gen4 rates.\u003c\/p\u003e\n\n\u003ch3\u003eIs 80 cm safe at Gen4 speed?\u003c\/h3\u003e\n\u003cp\u003eYes, Gen4 (16 GT\/s) tolerates this length on a well-built passive assembly. Keep the run as direct as possible, avoid sharp folds, and do not coil excess cable tightly against power rails.\u003c\/p\u003e\n\n\u003ch2\u003eIn the box\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e1 × MCIO 8x to 2 × MiniSAS HD cable, 80 cm (RMC74-8690-AX1)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eBacked by a 24-month warranty. If a link trains at reduced width or does not appear in the OS, send us your board and backplane models — width and pinout issues are usually identifiable from those two facts.\u003c\/p\u003e\n\n\u003ch2\u003eRelated\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/diliving.com\/collections\/mini-cooledge-iomcio\"\u003eAll MCIO \/ Mini Cool Edge IO cables\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/diliving.com\/collections\/minisas-hdsff-8643\"\u003eMiniSAS HD (SFF-8643) cables and adapters\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/diliving.com\/products\/mcio-x8-to-2x-u-2-nvme-adapter-sff-ta-1016-gen5-80cm\"\u003eMCIO x8 to 2× U.2 NVMe, PCIe Gen5, 80 cm\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"DiLinKer","offers":[{"title":"Default Title","offer_id":51617440170280,"sku":"RMC74-8690-AX1","price":43.88,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0866\/1460\/6120\/files\/main-1.jpg?v=1775192768"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0866\/1460\/6120\/collections\/1-1.jpg?v=1712029958","url":"https:\/\/diliving.com\/collections\/mini-cooledge-iomcio.oembed","provider":"DiLiVing","version":"1.0","type":"link"}